Multi-level parking lots in Dubai and other UAE cities need engineering solutions that provide not only daily air exchange, but also effective fire protection. UL Classified Dampers, devices that limit the spread of fire and smoke, maintain pressure control, and help maintain safe evacuation conditions, become a key element in such systems.
The role of fire-retaining and smoke valves
Various types of valves are used in modern buildings, including Fire Dampers, Smoke Dampers, Combination Fire & Smoke Dampers, as well as Static and Dynamic models. They are installed in openings of walls, ceilings and partitions to localize the source of fire and prevent smoke from moving into adjacent areas. UL Classified Dampers are rigorously tested according to international standards. These tests confirm the resistance to high temperatures, as well as the ability to maintain stability, integrity and thermal insulation for a given time. In conditions of multi-level parking, where a large number of vehicles are operated simultaneously, this level of protection becomes a mandatory requirement.
Pressure control and tightness
Parking lot ventilation systems operate under conditions of variable air flow. Extract Fans on the roof provide a general multiplicity of air exchange, and Jet Fans form a directional flow, moving polluted air to the exhaust points. For the efficient operation of these systems, it is important that the valves have a high degree of tightness. Well-chosen Smoke Dampers or Combination Dampers minimize air leaks and ensure pressure control. This is especially important for pressurization systems, which must maintain smoke-free escape routes. Reliable sealing reduces the load on the fans, improves the performance of the entire system and helps meet the requirements of civil defense and fire safety regulations.
Duct designs and valve compatibility
When designing systems, it is necessary to take into account the characteristics of the ducts. Fire Rated Ducts, certified for fire resistance up to 120 minutes, are used in conjunction with UL Classified Dampers. They can be static or dynamic, and can also be used in Curtain Type variants to cover large openings. The use of non-coated steel ducts or factory insulated systems allows you to maintain stability at full time-temperature curve. In the case of Smoke Extraction Ducts, the ability to withstand pressure and not reduce the cross-section at high temperatures is additionally monitored. The compatibility of the valves with the air ducts ensures the complete operation of the system in case of fire and complies with the standards applied in the UAE.
Monitoring and operational reliability
Multi-level parking lots require not only the right choice of equipment, but also competent design. At the planning stage, computational fluid dynamics (CFD) is used to determine the optimal location of Jet Fans and UL Classified Dampers. The operational parameters are taken into account during installation.:
- The free space around the Jet Fans is at least 500 mm at the entrance and several meters at the exit to form a flow.
- possibility of reversible operation of fans and valves for effective smoke extraction
- compliance with Civil Defense requirements in terms of fire resistance time and air tightness class.
In addition to fire resistance, energy efficiency and noise levels are important. Modern solutions allow you to reduce the energy consumption of Extract Fans and Jet Fans, while maintaining the necessary thrust for air circulation.
The choice to be made
Choosing UL Classified Dampers for multi-level parking ventilation systems in the UAE is a complex task. It includes evaluating the fire resistance of air ducts, selecting Fire, Smoke and Combination Dampers, pressure monitoring and leakproofness testing. Compatibility with Fire Rated Ducts and compliance with BS and ISO standards ensure that the system can withstand the effects of fire and smoke. For the rapidly growing cities of the region, reliable ventilation solutions in parking lots are becoming not just a technical requirement, but the basis of safety. UL Classified Dampers, combined with a well-thought-out Jet Fans and Extract Fans scheme, make it possible to control air flows, prevent the spread of smoke and maintain conditions for safe evacuation.